BGT » BGT Helicopter » Turbine Engine Starting; Ignition; Relight; and Shutdown
65.22 Turbine Engine Starting; Ignition; Relight; and Shutdown
65.22.2 Describe general procedures for starting and shutting down a turbine engine.
Turbine Engine Starting
Before starting, ensure all required pre-start checks have been completed in accordance with the aircraft or engine manufacturer's procedures.
A typical turbine engine start involves:
switching on the required electrical power;
positioning the engine controls for starting;
engaging the starter;
allowing the compressor to reach the required starting RPM;
introducing fuel and ignition at the specified point in the start sequence;
monitoring for a rise in turbine temperature;
confirming oil pressure develops within the required time;
monitoring engine RPM and other engine indications as the engine accelerates; and
disengaging or allowing the starter to disengage at the specified engine speed.
During the start, the pilot must monitor for abnormal conditions such as: